XSwitch

Galvanic isolation device for electric lines

  • Urban, inner, departmental communication
  • Director and dispatcher telephone
  • Loud radio transmission network
  • Impulse-driven clock
  • Sensors and fire alarm
  • Power networks
  • Lines connecting additional hardware (Refrigerator, fan, electric heater, air conditioning and other facilities)
  • Ethernet 10/100/1000 lines and other wire communication.

Purpose

Scalability

Device of GALVANIC isolation of electric lines

Designed to block all incoming and outgoing from the premises electrical circuits by their switching off or redirection, at the time of the secret negotiations.
Turns off majority of eavesdropping wired devices. The device has a modular design and consists of a different destination modules, whose number may vary depending on the problem and wishes of the customer.

Long-term trouble-free operation

The modular design
Multiple concurrent lines
  • XSWITCH POW is designed to receive the control signal and issuing power to the rest of the modules and contactors
  • XSWITCH 1E intended for 8 signal's opening lines (1 wire) type Ethernet 1000
  • XSWITCH 1E-CN intended for referral 8 signal's lines (1 wire) type Ethernet 10/100/1000 and other similar
  • XSWITCH SIGN is intended for 6 opening lines shock from 0.01 to ma 8a
  • XSWITCH SIGN-CN intended for referral 4 lines with shock from 0.01 to ma 8a
  • XSWITCH TP intended for two opening 4-wire telephone and low-voltage signal lines
  • XSWITCH TP-CN intended for one perrin the direction of wire telephone line

PRODUCT GALLERY

TECHNICAL SPECIFICATION

Case
Power is supplied by the network 220 +10% -15% / 50-60 Hz
AC voltage two-wire/cross-section 2x0.5mm
Connecting power consumed from the network no more than 14 W
Warm-up time not more than 0.1 sec
The weight of the device 2 kg
Dimensions of the device 360x180x103 mm
Numbers of chains that can be opened single-ended circuits 250V 20A 2 pcs
Numbers of chains that can be opened single-ended circuits 250V AC 8A 6 pcs
Numbers of chains that can be opened single-ended circuits 24V DC 8A 6 pcs
Numbers of chains that can be opened single-ended circuits 120V 0.02A 20 pcs
AC or 24V DC 0.1A Chains 1 pc (2 lines: central wire/screen braid)
The load capacity that can be opened simultaneously and the number of circuits depends on the modules included in the device